When To Use Multi-Function Safety Relays

PBUS-29-Automation-MultiFunctionSafetyRelays-400.jpg

July 13, 2021

By Lenny Filipkowski, Product Manager, Industrial Components, AutomationDirect

Many machines and robots require safety circuits to stop all or part of operation in the event of an emergency. Safety circuits are also used to keep all or part of a machine or robot from running while there is human activity in close proximity, either for normal operations or maintenance.

These safety circuits are typically configured using safety relays, or a safety-rated PLC or other safety-rated controller. But in many cases, multi-function safety relays are a better option (Figure 1). A multi-function safety relay is a configurable device with multiple inputs and outputs. It’s more powerful than a single-function safety relay, and less complex and expensive than a safety-rated PLC.

One or more multi-function safety relays can often be used to replace many basic single-function safety relays, simplifying installations and saving money. In other cases, multi-function safety relays can be used instead of a safety-rated PLC, resulting in substantial savings while streamlining implementation and maintenance.

Relays limit options

Multi_Safety_2.JPG

Machine and robot builder OEMs, and end users with similar applications, often have to monitor and control many I/O points that include a relatively small number of I/O points performing safety-related functions.

The most common safety circuit for simple machines with up to three safety inputs (such as an E-stop and two gate switches) is a basic single-function safety relay that has redundant contacts and is self-monitoring. As a machine or robot’s safety system requires more safety inputs, an option is to keep adding basic single-function safety relays, or to possibly go to a much more expensive safety-rated PLC.

Adding basic single-function safety relays to monitor and control the safety I/O often results in overly complex installations involving a relatively large number of relays. If zone control is desired, which requires certain parts of the machine or robot to continue operation for particular types of events, then the number of required safety relays can rapidly multiply, and complexity can grow exponentially.

When many relays are used, troubleshooting can be very difficult as each connection point and component need to be examined to determine the point of failure. Modifications are very difficult to implement as they require rewiring and often the addition of more relays.

In installations with four or more safety I/O points, one or two multi-function relays can often be used to replace four or more basic single-function safety relays, simplifying installations and saving money.

Multi_Safety_3.JPGThe benefits of this approach are listed in Table 1 and described below. Because fewer relays are required, less panel space is needed along with much less wiring. This cuts panel footprint and saves on upfront labor costs.

If changes are required to accommodate modifications to the machine or robot, or to add features, it’s much easier to reconfigure a multi-function safety relay, as opposed to adding more basic single-function safety relays.

Multi-function safety relays are available in a number of styles, including, but not limited to, dual channel monitoring with or without time delay, two-hand control, light curtain monitoring, speed monitoring, motor standstill monitoring, and relay extension to increase the number of output contacts.

These relays come in a wide offering of input and output configurations. A simple base unit can handle a variety of inputs, and expandable input and output modules can be added as needed. Multi-function relays do not need software for configuration or operation, so setup and maintenance is typically very straightforward and simple.

One specific type of multi-function safety relay allows desired functions to be set via a rotational switch at the front of the relay. It is designed to handle a variety of inputs such as E-stops, gate switches, light curtains and/or two-hand buttons—with appropriate outputs to trigger alerts and specific machine or robot operations.

Another type of multi-function relay provides more power through a combination of rotary and DIP switches that are used for initial configuration. This relay type typically can accommodate a much higher number of I/O, up to 24 inputs and 24 outputs, by utilizing separate input and output modules.

Multi_Safety_4.JPG

A system with an E-stop and two safety light curtains would require three single-function safety relays. Figure 2 shows the same system with a safety circuit consisting of just one multi-function relay, greatly simplifying the circuit while cutting costs and adding flexibility.

Simpler than a PLC

For zone control and other complex safety circuits, another solution is to use a safety-rated PLC to control and monitor just the safety I/O, or even all of the I/O, but this can be very expensive and can add unnecessary complexity.

Adding a separate safety-rated PLC in addition to the main controller requires the OEM to purchase, program and maintain a second programmable system in addition to the main controller. This safety-rated PLC will need its own programming software, with consequent renewal fees. The learning curve for a safety-rated PLC can be steep, and costs are relatively high.

Alternatively, one safety-rated PLC can be used to perform all required control and safety functions. This eliminates the problem of two separate systems, but it increases costs significantly, and generally only makes sense when a very large percentage of the machine or robot I/O is directly related to safety.

Multi_Safety_5.JPG

One or more multi-function relays can often be used to perform all safety-related functions for a machine or robot, resulting in substantial savings while simplifying implementation and maintenance as compared to a safety-rated PLC. The benefits of this solution are listed in Table 2 and described in detail below.

It’s typically much easier to configure a multi-function safety relay than it is to program a safety-rated PLC. There’s no need to purchase, update and maintain programming software, and a programming PC isn’t required.

A multi-function safety relay is easily integrated into the main control system by simply hard-wiring a few I/O points between the relay and the controller.

Because a multi-function safety relay is much less expensive than a safety-rated PLC, it often can be used to cost-effectively handle all of the safety-related I/O, obviating the need to upgrade the main controller to one that’s safety-rated.

Caveats and considerations

Very simple applications are often best served by one or two single-function safety relays and don’t require the added expense of multi-function relays. A machine, robot or other system that may only have an E-stop along with a set of light curtains or door switches is an example of an application where a single-function safety relay would be the best choice.

Multi-function relays do have their limitations and can only be expanded to a certain practical limit in terms of the total number of I/O points and complexity of function. Cost and particularly complexity can increase to a point where it makes sense to use a safety-rated PLC.

Very complex applications with many safety I/O points and multiple zone control, or applications with requirements that change substantially from machine to machine or over time, may be better served by using a safety-rated PLC, either for just the safety I/O or for all of the I/O.

Multi-function relays result in savings

Multi_Safety_6.JPG

A manufacturer of limit switches upgraded to a multi-function safety relay system for its production cell to accommodate increased automation of the processes used in the construction of its products (Figure 3).

The original safety circuit design was mostly manual, and thus required substantial operator interaction. The circuit had an E-stop, one set of safety light curtains, and door switches.

The newer automated production system required the addition of light curtain, door switches and safety mats at different locations within the production process. Different interlocking requirements such as speed monitoring of some of the equipment were also needed.

By automating the production process, the manufacturer was able to relocate eight employees to different functions in the company, and to increase production by 40%.

By switching to a multi-function safety relay instead of adding more single-function safety relays, the company saved 30% of the initial cost, and gained a much more flexible safety system.

The manufacturer did look at adding a safety-rated PLC, but the cost would have been more than 60% higher than the multi-function relay system, and the complexity of having to support such a system was not justifiable.

Conclusion

Machines and robots with just a couple of basic safety inputs such as an E-stop and one or two door switches or other safety-related inputs are typically best served by a safety system with one or two single-function safety relays.

When a machine has many I/O points, with a high proportion safety-related, a safety-rated PLC is often the best fit.

But for a machine or robot in between these two extremes, an easy to configure and inexpensive safety system using multi-function relays may be the preferred choice.

Source

AutomationDirect_Link_Logo.JPG

Multi_Safety_7.JPG

Related Articles


Changing Scene

  • Andreas Sobotta to Assume Role of Vice President North and South America for Pilz Automation

    Andreas Sobotta to Assume Role of Vice President North and South America for Pilz Automation

    Pilz Automation Safety Canada L.P. announces that their long-term CEO and GM, Andreas Sobotta, will assume the role of Vice President North and South America, effective immediately. He will still work from the Canadian office in Mississauga and visit all other subsidiaries in North and South America. Pilz will take their time to find a… Read More…

  • SEW-Eurodrive: MAXOLUTION System Solutions

    SEW-Eurodrive: MAXOLUTION System Solutions

    Whether in production or logistics operations, MAXOLUTION is synonymous with innovation in factory automation – across all industries and worldwide – helping you achieve your vision of an adaptable and resilient lean smart factory. Under the MAXOLUTION brand, SEW-EURODRIVE creates customized solutions for cutting-edge materials handling technology – from the shop floor through to IT.… Read More…


Sponsored Content
The Easy Way to the Industrial IoT

The way to the Industrial IoT does not have to be complicated. Whether access to valuable data is required or new, data-driven services are to be generated, Weidmuller enables its customers to go from data to value the easy way. Weidmuller’s comprehensive and cutting-edge IIoT portfolio applies to greenfield and brownfield applications. Weidmuller offers components and solutions from data acquisition, data pre-processing, data communication and data analysis.

Visit Weidmuller’s Industrial IoT Portfolio.


ADVANCED Motion Controls Takes Servo Drives to New Heights (and Depths) with FlexPro Extended Environment Product Line

Advanced Motion Controls is proud to announce the addition of six new CANopen servo drives with Extended Environment capabilities to their FlexPro line. These new drives join AMC’s existing EtherCAT Extended Environment FlexPro drives, making the FlexPro line the go-to solution for motion control applications in harsh environments.

Many motion control applications take place in conditions that are less than ideal, such as extreme temperatures, high and low pressures, shocks and vibrations, and contamination. Electronics, including servo drives, can malfunction or sustain permanent damage in these conditions.

Read More


Service Wire Co. Announces New Titles for Key Executives

Bruce Kesler and Mark Gatewood have been given new titles and responsibilities for Service Wire Co.

Bruce Kesler has assumed the role of Senior Director – Business Development. Bruce will be responsible for Service Wire’s largest strategic accounts and our growing Strategic Accounts Team.

Mark Gatewood has been promoted to the role of Vice President – Sales & Marketing. In this role, Gatewood will lead the efforts of Service Wire Company’s entire sales and marketing organization in all market verticals.

Read More


Tri-Mach Announces the Purchase of an Additional 45,000 sq ft. Facility

Tri-Mach Elmira Facility

Recently, Tri-Mach Inc. was thrilled to announce the addition of a new 45,000 sq ft. facility. Located at 285 Union St., Elmira, ON, this facility expands Tri-Mach’s capabilities, allowing them to better serve the growing needs of their customers.

Positioning for growth, this additional facility will allow Tri-Mach to continue taking on large-scale projects, enhance product performance testing, and provide equipment storage for their customers. The building will also be the new home to their Skilled Trades Centre of Excellence.

Read More


JMP Parent Company, CONVERGIX Acquires AGR Automation, Expanding Global Reach

Convergix Automation Solutions has completed the acquisition of AGR Automation (“AGR”), a UK-based provider of custom, high-performance automation design and systems integration primarily to the life sciences industry.

Following Convergix’s acquisitions of JMP Solutions in August 2021 and Classic Design in February 2022, AGR marks the third investment in Crestview’s strategy to build Convergix into a diversified automation solutions provider targeting the global $500+ billion market, with a particular focus on the $70 billion global systems integration and connectivity segments. Financial terms of the transaction were not disclosed.

Read More


Latest Articles

  • Making the Sustainable Transformation of the Process Industry a Success

    Making the Sustainable Transformation of the Process Industry a Success

    By Krystie Johnston and Dr. Manfred Jagiella – Sustainability facilitates opportunity when approached with a mindset to preserve resources and promote circularity. We share one Earth, and it is our global responsibility to care for it for the next generation. Endress+Hauser is one global company that understands this responsibility – and practices it as well.… Read More…

  • Why NOARK’s 12VDC Shunt Trip Coils for MCCBs Make Power Systems Reliable and Safer

    Why NOARK’s 12VDC Shunt Trip Coils for MCCBs Make Power Systems Reliable and Safer

    Circuit breakers are an essential component of any modern electrical system. Designed to protect your home or business from potential overloads or short circuits, these devices are your first line of defense against electrical fires. There are, however, situations where remote tripping of the circuit breaker may be required. It could be for operational reasons,… Read More…