Mersen Launches Class J Critical Power Panelboard

November 17, 2026
Class J Critical Power Panelboard Offers Enhanced Design Control & Improved Availability
Protect your critical power systems with Mersen’s Class J Critical Power Panel series panelboard
Mersen has announced a new addition to its portfolio of fully customizable fused panelboards. Mersen’s Class J Critical Power Panel (CPP) Series Panelboard is designed with critical power applications in mind. Mersen’s CPP offers installers quicker specification and easier installation, while offering customers a lower cost option. This lightweight panelboard, in a smaller footprint, and with in-house sourced components, translates into better design control and improved availability.
This UL 67 panelboard has multiple options for switched fused mains, up to 400A, featuring Mersen’s UL 98 rated Compact Fused Disconnect (CEP) and Amp-Trap 2000 Class J fuses for branch circuit protection. Fuses can be changed for the application to offer more time delay or faster protection based on the application. The panel, main, and branch circuits can be applied up to 600VAC or 125VDC. These benefits lead to a panelboard that is easy to apply, install, and maintain while serving your most important electrical loads.
Features & Options
- Integral Surge Protection (required on critical circuits)
- Feed Through Lugs
- Standard Dual/Sub Feed Lugs on MLO Mains
- Preconfigured options available
- Patented “Z” Bus Bar
Additional Benefits:
- Few connection points to minimize electrical/mechanical points of failure
- Robust steel back plate
- High interrupting rating – up to 200kA with up to a 400A fuse (main or remote)
- Easy selective coordination using Mersen Amp-Trap 2000 fuses or any other Class J fuses for branch circuit protection
Applications
Ideally suited for National Electrical Code (NEC) required and non-required applications such as:
- UPS Systems
- Data Centers
- Medium Voltage eHouses
- Emergency Circuits (required by NEC 700.27)
- Legally Required Standby Systems (required by NEC 701.18)
- Lighting loads or any load up to 30A
- DC applications for utility and railway markets
Specifications
Mechanical Characteristics
| Class CC | Class J | |
| cULus Certification | UL 67 & CSA 22.2 | UL 67 & CSA 22.2 |
| IEC Certification | IEC 60529 IP20 | IEC 60529 IP20 |
| Touchsafe Design | Personnel have no exposure to energized Components during operation of the system | Personnel have no exposure to energized Components during operation of the system |
Electrical Characteristics
| Class CC | Class J | |
| System Ampacity | 250A or 400A | 250A or 400A |
| Branch Circuit Ampacity | 30A CC | 30A and 60A J |
| Voltage Rating | 600VAC & 125VDC | 600VAC & 125VDC |
| Voltage Type | Delta or Wye / 1ph or 3ph / 2, 3, or 4 wire | Delta or Wye / 1ph or 3ph / 2, 3, or 4 wire |
| Withstand (SCCR) | 200kA with upstream protection (25kA standalone) | 200kA with upstream protection (25kA standalone) |
| Neutral | 100A, 200A, 250A Models: 200% neutral; 400A Models: 125% neutral | 100A, 200A, 250A Models: 200% neutral; 400A Models: 125% neutral |
Configurations
| Class CC | Class J | |
| Enclosure | UL 50 Type 1 | UL 50 Type 1 |
| Interior Only | Available as Single Unit | Available as Single Unit |
| Main Incoming | MLO: (1) #2 to 750 kcmil | MLO: (1) #2 to 750 kcmil |
| (2) 1/0 to 350 kcmil | (2) 1/0 to 350 kcmil | |
| o 2100A MFS: #2 t/0 | 100A MFS: #2 to 2/0 | |
| 200A MFS: #6 to 300 kcmil | 200A MFS: #6 to 300 kcmil | |
| 400A MFS: #2 to 600 kc mil | 400A MFS: #2 to 600 kc mil | |
| Single Cable | (2) #4-4/0 Compression Lug | (2) #4-4/0 Compression Lug |
| Single Cable | #4-4/0 Crimp Lug | #4-4/0 Crimp Lug |
| Parallel Cables | #8-1/0 Compression Lug | #8-1/0 Compression Lug |
| Parallel Cables | #8-1/0 Crimp Lug | #8-1/0 Crimp Lug |
| Branch Configuration | Double Column | Double Column |
Circuitry
| Class CC | Class J | |
| Circuits | 24, 36, 42 | 30A J series: 24CKT, 36CKT, 42CKT60A J series: 6CKT, 12CKT, 24CKTHybrid 30A/60A J series: 24CKT/6CKT, 24CKT/12CKT |
Compatibility
| Class CC | Class J |
| For use with Mersen Model CEP – Compact Fused Disconnect | For use with Mersen Model CEP – Compact Fused Disconnect |
The Class J Critical Power Panel joins Mersen’s Class CC Critical Power for a complete offering to suit many needs.
The Mersen Critical Power Panel is a highly configurable panelboard with many options. Please contact Mersen Technical Services at 978-248-8914 or email: fusedpanelboards.ep@mersen.com for submittal and bid packages.
For more information on Mersen solutions HERE



Class J Critical Class J Critical Class J Critical